Duct Smoke Detectors

Accessories 581S/592SC

592SC

  


 591S

    

   

The remote accessories are designed to be used with FireX duct smoke detectors to provide the most complete functionality ever available in such a device. The remote accessory is available with either the single gang remote indicator/control (591 models), or with the addition of a single gang strobe assembly (592 models). Both versions are compatible with standard Decora style cover plates (choice of white, red or stainless steel). A strobe-only version (593 models) is available for retrofit upgrade of “controller only” installations.

 

The indicator/control assembly provides:

§         Visual indication of detector Pilot, Trouble and Alarm Functions

§         Selectable audible indication of Alarm, Trouble or both

§         Buzzer Silence function, with silenced indication and “ringback” following condition correction

§         Lamp/Buzzer test function

§         Key-Operated detector Test and Reset functions

§         Lever-operated “No-Tools” terminal block

§         Port for plugging in the optional strobe assembly

§         Black “DUCT SMOKE DETECTOR” decal included for front plate

§         Blue “SMOKE”, red “FIRE” strobe lens decals included for both horizontal and vertical mounting

 

Strobe Connection

The strobe assembly provides visual indication of alarm conditions, and is connected to the indicator/control assembly via the provided polarized connector. To install the strobe module, simply plug the provided connector onto the pins as indicated on the rear of the indicator/control module. Snap the strobe lens into the cover plate, and install cover plate following completion of remote module wiring.

 

NOTE: The strobe and audible buzzer features are not ADA compliant, and not intended for life safety notification or evacuation purposes (public mode). These functions are for duct smoke detector status indication only (private mode).

 

Audible Buzzer Configuration

There are two jumpers located on the rear of the indicator/control assembly. To enable audible buzzer operation for Alarm or Trouble conditions, simply leave the jumpers in place. To disable either or both functions, remove the appropriate jumper(s).

 

Silence and Ringback Functions

On the occasion where an audible alarm or trouble condition needs to be silenced while the detector condition is inspected and remedied, the indicator/control module provides a silence function. The slide switch located on the front of the module is pushed DOWN to activate the silence function.

 

Upon correction of the notified condition, the silenced buzzer will resume sounding. The ringback feature serves as a reminder to reset the silence switch to the “normal”, UP position. Note that the strobe module, when installed, will not stop operating when the silence function is engaged.


For more information, please review the technical specifications.